简介:摘要:CRH380B型动车组电气连接的可靠性和安全性是动车组安全运行的保障,由于动车组属于轨道交通运输系统,这就要求动车组的电气连接在系统设备维护的过程中不能过于复杂,只有这样才能更好的将其应用在高速动车电气系统当中,为人们的交通出行带来方便。当前的接线方式主要分为端子接线、连接器接线、端子排接线等。CRH380B动车组生产和运营过程中,曾发生过多次因插头制作、连接不良造成的开口项和运营故障,其中主断路器插头发生缩针、虚接、损坏、连接不良等故障,影响高压电气设备的电气功能,导致主断路器不能正常工作,报故障后可能出现不能自动闭合情况,引起主断路器损坏,影响动车组的运行。
简介:Ecologicalswitchgearconceptforsecondarydistribution,Effectofdynamicforcecompensationinalowvoltagevacuumcircuitbreaker,Futuretrendsindevelopmentoflow-voltagevacuumswitchgear,Influenceofgradingcapacitorsonthebreakingperformanceofa24-kVvacuumbreakerseriesdesign,Investigationofdielectricbreakdownprobabilitydistributionfordouble-breakvacuumcircuitbreaker,MeasurementofSurgePropagationinInductionMachines。
简介:AhybridrepetitiveopeningswitchforinductivestoragesystemsandprotectionofDCcircuits,Analysisofelectrodeforvacuuminterrupterswithnonuniformaxialmagneticfield,CalculationofelectricfieldinvacuumcircuitbreakerusingoptimizedandtraditionalCSM,CurrentZeroBehaviorofVactoomhlterruptersWithBipolarandQuadrupolarAMFContacts
简介:Investigationofhotgasflowinadead-tank-typegascircuitbreaker,Newconcept145kVintegratedairinsulatedswitchgear,NumericalanalysisofcoldflowingascircuitbreakerconsideringthepropertiesofSF6,Optimaldesignofgascircuitbreakerforincreasingthesmallcurrentinterruptioncapacity,RDDS(rateofdecreaseofdielectricstrength)measurementforgascircuitbreaker,RelationbetweenGasBlastCharacteristicsandGasPassageStructureoftheThermalPufferTypeGasCircuitBreaker。
简介:ABasicStudyofControlledClosingforTransformerswithResidualFlux;AnapproachtotheoptimuminsulationdesignofGCBinterrupter;Analysisontheforcesgeneratedinpuffertypecircuitbreaker;Calculationoftransientpufferpressurerisetakingmechanicalcompression,nozzleablationandarcenergyintoconsideration;ComparisonofevaluationmethodsofthesmallcurrentbreakingperformanceforSF{sub}6gascircuitbreakers;Deteriorationdiagnosistechniqueofhousingrubberforcompositehollowinsulators;
简介:Developmentofsinglebreak420kVGCB,Developmentofsynchronousswitchingcontrollerforgascircuitbreakers,EMTPsimulationofSLFinterruptingperformancefortwaseriallyconnectedarcswithdifferentarcparameters,Feasibilitystudyonapplicationofhighvoltageandhighpowervacuumcircuitbreaker.
简介:摘要断路器是110kV电网系统中非常重要的电能调控与分配调度的核心电气设备,其运行安全可靠性直接影响到整个110kV电网系统能否具有较高的运行安全可靠性和节能经济性。实际电能输电、配电、用电过程中,无论采用何种导电材料进行电能资源的传输,其均存在材料值阻,即在供电电流和电压相互作用环境下,就会产生相应的热损耗,一旦断路器触头联接部位等处,由于各种原因造成其接触电阻值增大,则会导致主回路电阻值增大,相应运行中的发热量将会在这些部位积聚,正常散热量无法有效排除,进而使这些部位的温度不断升高,当温升超过断路器触头、接头等材料的最大允许温度值时,就会引起发热故障,轻者引起断路器动作性能降低,重者将会引起设备严重烧损事故。运行中的断路器由于生产制造、原材料、检修维护等原因会引起设备发生温升故障,如不及时发现并采取相应措施进行有效处理就会引发较为严重的安全生产事故。