简介:AdsorptionofCr(VI)andp-chloroanilineonthreetypicalsoilcolloidsandpHinfluencewerestudiedusingbatchequilibriummethod.BothofCr(VI)andp-chloroanilineadsorptiononthecolloidscouldbewelldescribedbygeneraladsorptionsimulationequations,TheadsorptionprocesseschangedwithmediapH.WhenCr(VI)andp-chloroanilinecoexistedonsoilcolloids,theirinteractionscouldbeobservedinacertainpHrangetobeaccompaniedwithCr(VI)reduction,whichclearlysuggestedthatasurfacecatalyticreactionoccurredinthissystem.SoilcolloidactedasaneffcientcatalystfortheinteractionofCr(VI)andp-chloroaniline.ThepHvaluesatwhichnointeractionwasobservedwere4.0,4.5and5.0forthecolloidsofindigoticblacksoil,yellow-brownsoilandlatosol,respectively,Capillaryelectrophoresisusedtoanalyzep-chloroanilineprovidedahighseparationefficiencyandshortseparationtime,andneedednomoreextensivepretreatmentofsamples.
简介:摘要CR400BF-A型动车组具有保持制动功能,在列车网络通信正常的情况下,由列车制动管理者(以下简称TBM)根据设定的施加、缓解逻辑统一控制全列保持制动的施加和缓解。同时列车设计自复位手动缓解按钮、保持制动故障开关和保持制动缓解列车线,可以实现手动缓解和故障情况下的保持制动切除操作。本文对保持制动的分析主要有以下几个方面保持制动逻辑控制,保持制动缓解列车线,BCU内部控制电路,保持制动故障处理。
简介:摘要目的探讨低剂量CR在胸部的应用价值。材料和方法收集150例健康体检低剂量胸部CR,低剂量采用120kV,160mA,16ms,1.8米距离站立位摄片;常规剂量组除曝光时间采用32ms外,其它扫描参数同第一组。结果1.全部病例在32ms及更小剂量条件下获得可以用于筛检的图像,不必使用高条件。多数病例在16mAs条件下可以获得适用于筛检的图像(62例,77.5%),少数可以用更小剂量(16例,10.6%),其余需要稍高条件(38例,25.3%)。2.16ms剂量组图像良好,补充的8ms图像欠佳者,其身高体重比的95%可信区间1.00~1.03;16ms剂量组图像欠佳,24ms图像良好者,其身高体重比的95%可信区间1.13~1.22;16ms剂量与8ms剂量图像均良好者,其身高体重比的95%可信区间0.83~0.88。结论身身高体重比小于0.9时可采用8ms,0.9~1.05时可采用16ms,大于1.05时应采用24-32ms,作为筛检,一般可以不用更大的剂量。
简介:SomelaboratorydiffusiontestswereconductedwithdiffusiondevicetodeterminethediffusioncoefficientofCr(Ⅵ)ionpassingthroughDalianredclaysamples.TheconcentrationsofCr(Ⅵ)atdifferentplacesofthesampleswerethenmeasuredspectrophotometricallyafterastandingtimeof1000d.Aone-dimensionalsolutetransportequationwasusedtosimulatethetransportofCr(Ⅵ)throughclaysamples.Back-calculationofdiffusioncoefficientofCr(Ⅵ)wasmadewithfinitedifferencemethod.Parametricanalysiswasconductedtosimulatevariationsinsoildrydensity,temperature,pHandstandingtime.Theresultsshowthatthemethodusedinthispaperissimpleandeffective.ThediffusioncoefficientofCr(Ⅵ)inDalianredclayvariesfrom1.50×10-7cm2/sto2.08×10-7cm2/s.After1000ddiffusion,theconcentrationofthesourcesolutiondropsdownto1.27mg/Lfrom62.5mg/L,andthediffusiondistanceisonly3.5cm.Undertheassumptionthatdiffusioncoefficientisconstant,thediffusioneffectbecomesmoreobviouswithlowerdensity,lowertemperature,higherpHvalue,andmuchmoretime.
简介:摘要CR400BF-A型动车组具有保持制动功能,在列车网络通信正常的情况下,由列车制动管理者(以下简称TBM)根据设定的施加、缓解逻辑统一控制全列保持制动的施加和缓解。同时列车设计自复位手动缓解按钮、保持制动故障开关和保持制动缓解列车线,可以实现手动缓解和故障情况下的保持制动切除操作。本文对保持制动的分析主要有以下几个方面保持制动逻辑控制,保持制动缓解列车线,BCU内部控制电路,保持制动故障处理。
简介:以便改进金属压路机的表演,Mo+Y2O3合金粉末由CO2激光为激光表面alloying处理在40Cr钢压路机底层的表面上一致地习惯于上衣,结果证明许多好后果在增加稀土元素氧化物Y2O3以后被获得。合金层的水晶谷物显著地被精制。水晶谷物的边界被加强。微观结构的一致性和密度被增加。坚硬和合金层的穿的抵抗更加被改进。合金层的原子价电子结构分析被固体和分子(EET)的实验电子理论做。计算结果证明Y应该在第一个阶段被混合,Fe应该在第十八个混合乐队。说明的分析结果稳固的答案的电子理论在alloying上显示出加强的效果层,它提高了契约并且证实了试验性的结果。
简介:目的探讨肋骨骨折的CR应用价值。方法对已确诊的500例胸部外伤患者,均行CR及传统X线平片检查,其中32例诊断较为困难者,行透视下切线位点片。结果本组500病例共检出肋骨骨折612处,3种方法检出率分别为84.80%、91.99%、8.01%。结论CR能够早期诊断肋骨骨折,尤其对腋中线、肋部及膈下骨折,检出率高于传统x线平片,与透视下切线位点片比较,尚存在体位单一固定,切线角度不易准确把握,不能及时观察肋骨动态结构改变之不足,但CR操作简便,灵活快捷,图像清晰,后处理功能强,可及时弥补其不足。我们认为CR检查结合透视下点片应为最佳检查手段。
简介:对防化研究院某研究所生产的SY-2型CR39探测器与美国Battelle公司生产的CR39探测器进行了快中子灵敏度对比和SY-1型CR39探测器与日本CR39探测器进行了α粒子注量与径迹密度线性关系对比。实验结果证明:防化研究院某研究所生产的CR39探测器与国外同类产品具有相同的快中子灵敏度和同样较好的α粒子注量与径迹密度线性关系,其性能和国外同类产品基本相同。